Delivering quality patient care under today's cost constraints can be a daunting task. That's why we have the PC. Sharing many of the same features as our popular premium pressure wound systems, the PC (which stands for Primary Care) offers two low-cost alternatives: the PC Alternating Pressure Relief System , or the PC Low Air Loss system.
Quality Pressure Wound Treatment with a Prospective Price.
Using leading-edge technology and materials, the PC is engineered by SenTech to insure quiet, reliable operation that won't fail you or your patient.
Better than any other product in its class, both of SenTech's PC support systems provide aggressive pressure wound treatment that benefit not just your patients, but your budget too.
Most lower-priced systems on the market today utilize imported low capacity controllers which due to their low pump output are continuously working at their upper design limits. As a result, they may have a short life span and reliability problems. Now with the PRIMARY CARE family of products, caregivers can have a low-cost alternating pressure relief system without compromising features or reliability.
Cost Effective Pressure Relief
Alternating Pressure (AP) Relief provides complete deflation of every other air cell on a 5 minute cycle.
Pressure sensor technology insures a consistent, accurate desired pressure. Both versions are customizable for individual patient needs — just by setting patient weight.
Both systems include a quilted, breathable, anti-shear, water resistant top cover.
Rapid deflate CPR pull conveniently located at the head of the mattress to aid in quick rescues.
Energy efficient — equivalent to less than that of a 25-watt bulb.
Lightweight, service-free.
Electronic Controller features:
- Choice of Alternating Pressure or Low-Air- Loss
- Pressure sensor technology insures a consistent, accurate desired amount of pressure
- Both systems are customizable for individual patient needs- just by setting patient weight
- Alternating Pressure Relief provides complete deflation of every other aircell on a 5 minute cycle
- Low-Air-Loss system features a series of low-air-loss vent hoses, and allows for adjustable rate of airflow
- Energy efficient - equivalent to less than that of a 25-watt bulb
Mattress Replacement includes:
- 20 individual air cells
- 5 1/4 inflated air cell height
80"L x 36"H
- Flexible straps secure to any bedframe
- Supports patients up to 280 lbs
|
- Water resistant, vapor permeable, anti-shear coverlet with plush quilting
- Zippered, sealed design
- Rapid deflate CPR pull
|
Specifications
Electronic Controller –
Physical Dimensions:
Height (Inches) 8
Width (Inches) 8 (9, including air ports)
Depth (Inches) 4
Weight (Pounds) 6
Electrical Specifications:
US and Canada:
UL2601 Classification Class II
Type B
Power Requirements 120VAC, 60Hz
External Fuse 2A 250V, Fast Acting (UL-Approved)
Maximum Current < 0.5A
Ground Earth
Operating Parameters:
Weight Range (Pounds) 80-280
Environmental Conditions:
Operating Conditions:
Ambient Temperature (oC) +10 to +40
Relative Humidity (%) 30 to 75
Atmospheric Pressure (hPa) 700 to 1060
|
Storage/Shipping Conditions:
Ambient Temperature (oC) -20 to +70
Relative Humidity (%) 10 to 100
Atmospheric Pressure (hPa) 500 to 1060
Mattress Replacement (Fully-Inflated) –
Physical Dimensions
Height (Inches) 7 (Replacement)
5.5 (Overlay)
Width (Inches) 36
Length (Inches) 80
Weight (Pounds) 22
Limited Warranty:
Compressor Pump : 2 years
Electronic Controller : 1 years
Soft Goods: 1 Year
Battery: 6 months
Recliner Chair: 2 years |
|
|